Language
Message/News
[Important] Updated on 24th April, 2018.
With latest Windows 10 (version 1709, OS build 10.0.16299), the learning status does not work.
Please check the new settings in the "PC Setting" to solve this.

[Important] Updated on 7th February, 2018.
Now using Adobe Flash Player to view WBT courses.
Adobe has released security updates for Adobe Flash Player for
Windows, Macintosh, Linux and Chrome OS.
These updates address critical vulnerabilities that could lead
to remote code execution in Adobe Flash Player 28.0.0.137 and
earlier versions.
Visit following link to update flash player.
https://get.adobe.com/flashplayer/


[Important]: Updated on 19th May, 2016
◆Using Windows 10
If you use Windows 10, you can not login with Microsoft Edge, default browser.
So please use another installed browser, Internet Explorer 11.
Refer to "PC Setting", how to open Internet Explorer 11.
Thank you.

[Important]: Updated on 26th September, 2014
Please modify your PC setting as "PC Setting"
because WBT Server has replaced with new URL.
And also change a favorite asap if you have,
because the URL is different from before.
Thank you.

[New WBT Information] Update on 20th October, 2014
New 5 WBT courses have been published as follows.
Please utilize new courses.

♦ Installation
- Useful Points for On-site Brazing Work

♦ Product Knowledge
- Overview of i-Touch Manager System
- Functions of i-Touch Manager 1: Monitoring & Operation
- Functions of i-Touch Manager 2: Automatic control
- Test Operation of i-Touch Manager


[Important]: Updated on 26th September, 2014
Please modify your PC setting as "PC Setting" because WBT Server has replaced with new URL. And also register a favorite again if you have, because the URL is different from before.
Thank you.


[Important]: Updated on 1st April, 2013
If you find a mistake in your course status or your PC gets stuck for some reason, please contact global.training@daikin.co.jp along with your login ID and the course name in question.



DL
Introduction to WBT
What is WBT?
Flow from Application to Completion
Application
WBT Login
Hardware Requirements
PC Setting
Terms of Service
Currently Offered Courses
Local Group Training Courses
FAQ

Inquiries
Global Training Group
Training Department
Daikin Industries, Ltd.
e-mail


Administrator's Room
 
 
Currently Offered Courses
   Basic Air Conditioning
     Introduction to Air Conditioning
     Classification of Air Conditioning Systems
     Principles of Refrigeration
     4 Components of Refrigeration Cycle & How It Works
     4 Components of Refrigeration Cycle & 4-way Valves
     Basic Knowledge of Heat and Pressure
     Standard Operation State
     Impact of Various Changes on Operation State
     Simple Heat Load Calculation
     Model Selection of Air Conditioners
     The Basic Knowledge of Analog Relays
     Refrigerant Types and Nomenclature
     Air-cooled And Water-cooled Air Conditioners
     Primary Electrical Components of Air Conditioners
     Primary Electronic Components of Air Conditioners
     The Primary Components of the Refrigeration Cycle Other than the Four Principle Components
     The Primary Safety Devices of the Refrigeration Cycle
     The Basics of Ventilation : Ventilation Methods and Required Ventilation Volume
   Psychrometric Chart
     How to Read Psychrometric Chart
     Utilization: Mixture of Air
     Utilization: Heat'g, Humid., Cool'g & Dehumid.
   P-h Chart
     Introduction to P-h Chart
     P-h Chart and Coefficient of Performance
   Basic Work
     How to Use Testers and Clamp Meters
     How to Use Megger Testers and Thermometers
     How to Use Gauge Manifolds
     Flaring Procedures
     Procedures for Refrigerant Pipe Bending(Pipe Benders)
     Setting of Acetylene Welders
     Flare Connection and Handling of the Service Ports and Stop Valves
     Vacuum Drying
     Procedures for Additional Refrigerant Charge (Model: Sky Air; Refrigerant: R410A)
     Pump Down Procedures
     Procedures for Refrigerant Recovery
     Air Tightness Test
     Basics of Brazing Work
     Points for Brazing Work When Replacing Parts (1) - Compressor etc.
     Points for Brazing Work When Replacing Parts (2) - Repairing
   Test Run
     Inspections Prior to Test Run - Sky Air / VRV Edition -
     How to Measure Test Run Data -Sky Air Edition-
     How to Measure Test Run Data -VRV Edition-
   Troubleshooting
     Wired Remote Controller : How to Use "Inspection" Mode
     Wireless Remote Controller How to Use the "Inspection" Mode
     Wired Remote Controller : How to Use the Service Mode
     Wired Remote Controller : Malfunction Codes
     Methods of Diagnosing Malfunction Codes: A3 and AF
     Methods of Diagnosing Malfunction Codes: A0
     Methods of Diagnosing Malfunction Codes: E3 and JA
     Methods of Diagnosing Malfunction Codes: E4 and JC
     Methods of Diagnosing Malfunction Codes: E6 and J2
     Methods of Diagnosing Malfunction Codes: C4
     Methods of Diagnosing Malfunction Codes: A9 and E9
     Methods of Diagnosing Malfunction Codes: U5 and U8
     Methods of Diagnosing Malfunction Codes: U4 and U9
     Methods of Diagnosing Malfunction Codes: L5, L8 and L9
     Methods of Diagnosing Malfunction Codes: U1, U3 and UF
     Malfunction Diagnosis using Outdoor Unit PCB
     Malfunction Diagnosis using Centralized Control Devices
   Installation
     Pre-installation Checks
     Installation Flow and Precautions
     Examples of VRV Installation Problems (Indoor Units)
     Examples of VRV4 Installation Problems (Drain Piping and Piping Clamping)
     Key Points of VRV Refrigerant Piping Installation
     Key Points of Drain Piping Installation (VRV and Sky Air)
     Remote Control Wiring
     Overview of VRV Control Wiring and Wiring Precautions
     Indoor Unit Installation Points
     Key Points for VRV Outdoor Unit Installation
     Local Setting With Remote Controller
     Field Setting With Outdoor Unit PCB
     Field Setting VRV IV Outdoor Unit PCB
     Setting Display and Operation Methods of Outdoor Unit PCB Differences between VRV III and VRV IV
     Content of Outdoor Unit PCB Settings Differences between VRV III and VRV IV (General)
     Content of Outdoor Unit PCB Settings Differences between VRV III and VRV IV (For Europe)
     Operating Instructions and Delivery - Sky Air Ceiling Mounted Cassette Type -
     Useful Points for On-site Brazing Work
   Product Knowledge
     Principles of Reluctance DC Motors
     Principles of Inverter Control
     Why are Inverter ACs Energy Efficient?
     Nomenclature -Split-
     Nomenclature -SA-
     Nomenclature -VRV-
     VRV System Features
     Refrigerant Pipe Selection for the VRV System (For Asia, Australia)
     Refrigerant Pipe Selection for the VRV System (For Europe)
     Refrigerant Pipe Selection for the VRV IV System (for Asia, Australia)
     Duct Design Procedures for the Ceiling Mounted Built-in Type
     The Basics of Sound
     Soundproofing Plans for AC Equipment
     D-BACS (Centralized Controller)
     Key Points when Designing a D-BACS System
     Evolution of VRV
     Overview of i-Touch Manager System
     Functions of i-Touch Manager 1: Monitoring & Operation
     Functions of i-Touch Manager 2: Automatic control
     Test Operation of i-Touch Manager
     VRT Control
   New Refrigerants
     Fluorocarbons and the Earth's Environment
     Properties of New Refrigerant & Key Points for Use
     Properties of R32 and Key Points for Use
     Montreal Protocol Kigali Amendment
   CS (Customer Satisfaction)
     Customer Satisfaction for Service Engineer
   Danger Prediction Training
     Ceiling & Roof Work
     Transporting Work
     High-pressure Gas Transporting Work
     Brazing Work
     Electrical Work